Item
|
Title |
Manufacture |
Model |
Description |
Image |
1. |
Material afety data sheets |
sigma-Aldrich
|
--- |
3 volume set of gma’ Aldrich
material afety data sheets | |
2. |
Eppendorf entrifuge |
Eppendorf |
5415 |
laboratory centrifuge |
|
3. |
2 liter fermentation system |
New Brunswick |
--- |
2 liter fermentation system complete with oxygen, ph, metering pumps |
|
4. |
20-100 liter distillation system |
Buchi |
R-176 explosion proof |
20-100 liter buchi r-176 rotary evaporator with two (2) 10 liter receiver
flasks.Complete system, except “u” bend on top3 phase power |
|
5. |
Gow mac gas leak detector |
Gow-Mac |
21-250 |
Gas leak detector for gas chromatographs |
|
6. |
Nash liquid ring vacuum pump 316 stainles steel |
Nash engineering |
SH-6 |
Nash liquid ring vacuum pump 750-1000
cfm at 25” all 316 stainless steel wetted parts |
|
7. |
HPLC auto sampler |
Spectro physics |
SP8880 |
HPLC autosampler with de gasser unit |
|
8. |
Dry vacuum pump 250 cfm at 1 mm hg |
Stokes |
575 vacuum pump with 306 blower unit |
Dry vacuum pump 250 cfm at 1 mm hg
for distillation with control panel |
|
9. |
1000 gallon air pollution control tower all glass |
Pfaulder |
--- |
All
glass air poluution control scrubber
a, bout 1000 gallon water capcity,
has packing material and de-mister.
Unit is glass enamled steel |
|
10. |
10 gallon reactor stainless steel |
--- |
--- |
10
gallon stainless steel reactor
with bottle outlet and jacket.
Has numerous openiongs for condensors,
additions and sight glass and
temp monitoring |
|
11. |
stokes
vacuum shelf dryer 50 square feet,
11 shelves |
stokes |
--- |
stokes
vacuum shelf dryer, 11 shelfs,
50 sq. feet, 71 inches height
x 55” width x 46 “
depth
|
|
12. |
nutsche
filter 50-100 kgs capacity stainless
steel
|
--- |
--- |
vacuum
filter, 50-100 kg capacity with
160 liter liquid capacity
All stainless steel construction
Nuts he type filter, approx 2
meters Bottom filter screen. 2"
center bottom outlet.
|
|
13. |
12
port vacuum manifold system for
solid phase extraction –SPE
|
alltech |
all tech 210351 |
vacuum
manifold for 12 samples with vacuum
gauge |
|
14. |
savant
refrigerated vacuum trap |
savant |
savant rvt400 |
Savant
RVT400 Refrigerated Vapor Trap
powers, cools very quickly and
is in good physical condition.
CFC Free!! Picture of the inside,
you can see the ice forming. Opening
measures approx. 7.25"w and ...
|
|
15. |
Pope wiped film evaporator 4 inches |
Pope scientific |
4 inches |
Efficient
thermal separation with minimum
product decomposition and maximum
product quality; these are results
you can expect using Wiped Film
- Short Path process for distillation,
evaporation, concentration, separation,
purification or deodorization.
Performance is superior to flash
evaporators, falling film stills,
rotary evaporators and other equipment,
in any processing application
where heat-sensitivity is a factor.Pope
Short Path/Wiped-Film Stills (WFS)
and Wiped-Film Evaporators (WFE)
successfully separate volatile
from less volatile components-
Examples - click (Oils, Fats,
Chemicals, Polymers, Nutraceuticals,
Fragrances, etc.), with a gentle
process utilizing the thin-film
wiping action of feed liquid through
a heated cylindrical vacuum chamber. |
|
16. |
Chromatotron |
Cyclograph |
87-40 |
Separated
up to 4 grams of product on a
radial centrifuge lawyer chromatography
centrifugal thin layer chromatography.
Centrifugally accelerated radial,
thin layer chromatograph Variable
speed motor, processing time 20-30
minutes |
|
17. |
200 gallon jacketed distillation unit.
316 stainless steel
|
--- |
--- |
Size
200 gallon tank with carbon steel
jacket. Max temp 450F, max pressure
60- psi |
|
18. |
Rotary cone
dryer, jacketed stainless steel
40 cubic foot
|
--- |
--- |
Approx
50 cubic feet working capacity,
316 stainless steel. Maximum material
density 65 pounds a cubic foot.
Carbon steel jacket. 60"
diameter x 22" straight side
x 30" cones. 18" diameter
top charge with cover, 16"
center bottom outlet with drum
lift. Internal agitator bar driven
by a 3 hp, 3/60/230/460d |
|
19. |
Heat
exchanger glass, thimble 9 square
foot |
Pfaulder |
Thimble style |
Heat
exchanger, glass lined 5”6
long x 14 “. Carbon steel
jacket, 9 sqaure foot. Shell has
1-1/2: oipenings for cooling fluid |
|
20. |
Sihi liquid ring vacuum pump |
Sihi |
CEHQ |
53
cfm at 1450 rpm, liquid ring vacuum
pump. Carnon steel construction.
Driven by a 7.5 hp motor
|
|
21. |
Laboratory
mixer arrow |
Arrow |
1750 |
Overhead mixer,
high torque adjustable speed ranges
from from 0-1000 rpm |
|
22. |
karl fischer titratord
|
Metrohm |
775 dosimat titrator |
karl
fischer titrator performs coulometric
and volumetric karl fischer titrations
Metrohm 775 Dosimat Titrator. At a favourable price, the 775
Dosimat offers you the advantages
essential for dispensing, namely
extremely high accuracy and the
possibility to use modern Exchange
Units with a flat PCTFE/PTFE or
ceramic stopcock. One of its many
application possibilities is manual
titration |
|
23. |
Perkin
Elmer 1320 Grating Infrared Spectrophotomet |
Perkin elmer |
1320 |
Description: Perkin Elmer 1320 Grating Infrared
Spectrophotometer- Our units ship
with a new solid state detector
installed not using salt windows,
specifications equal or better
than new and long lasting detection
system, Automatic-recording, double-beam,
optical null instrument which
features microprocessor-controlled
abscissa functions, a DC wedge/pen
servo mechanism, a four-digit
frequency readout, and a touch-control
panel. The monochromator, photometer
and electronics compartment houses
the grating monochromator, the
detector, and the associated electronics.
The source compartment contains
the source, the power supply and
the fuses.Abscissa Range 4000
- 600 cm-1Abscissa Accuracy 4000
- 2000 cm-1: ±6 cm-12000
- 600 cm-1: ±3 cm-1Abscissa
Expansion x0.5, x1, x5Ordinate
Accuracy ±2 TOrdinate Repeatability
within 0.75 T100 Line Flatness
±3 TSignal/Noise Better
than 100:1Resolution (Narrow Slit
Program) 3 cm-1 at 1000 cm-15
cm-1 at 3000 cm-1Stray Light <
1T (4000 - 450 cm-1)< 2T (450
- 250 cm-1)< 3T (250 - 200
cm-1)Time Drive 0.5, 1 and 5 cm/min |
|
24. |
Perkin Elmer 1310 Grating Infrared Spectrophotomet
|
Perkin elmer
|
1310 |
Perkin Elmer 1310 Grating Infrared Spectrophotometer-
Our units ship with a new solid
state detector installed not using
salt windows, specifications equal
or better than new and long lasting
detection system, Automatic-recording,
double-beam, optical null instrument
which features microprocessor-controlled
abscissa functions, a DC wedge/pen
servo mechanism, a four-digit
frequency readout, and a touch-control
panel. The monochromator, photometer
and electronics compartment houses
the grating monochromator, the
detector, and the associated electronics.
The source compartment contains
the source, the power supply and
the fuses.Abscissa Range 4000
- 600 cm-1Abscissa Accuracy 4000
- 2000 cm-1: ±6 cm-12000
- 600 cm-1: ±3 cm-1Abscissa
Expansion x0.5, x1, x5Ordinate
Accuracy ±2 TOrdinate Repeatability
within 0.75 T100 Line Flatness
±3 TSignal/Noise Better
than 100:1Resolution (Narrow Slit
Program) 3 cm-1 at 1000 cm-15
cm-1 at 3000 cm-1Stray Light <
1T (4000 - 450 cm-1)< 2T (450
- 250 cm-1)< 3T (250 - 200
cm-1)Time Drive 0.5, 1 and 5 cm/min
File Photo of Similiar Instrument |
|
25. |
Buchi
Vacuum controller |
Buchi |
B-721 |
Buchi
vacuum controller with vacuum
solenoid valve. efficiently controls
vacuum levels from <10mbar
to atmospheric pressure, electronic
switching turns V500 on and off,
with controller and compact housing, |
|
26. |
Water
flow monitor:FM110 Flow Monitor,
0.5L/Min - 15L/Min |
Electrothermal |
FM110 (Fisher scientific Cat)11-164-41
|
The FM110 Flow Monitor is used to
monitor the flow of aqueous liquids.
If the liquid flow reduces significantly
for a period of approximately
10 seconds a red LED indicator
will light and an audible alarm
will sound. At the same time the
electrical power to the equipment
under control will be disconnected.
A switch on the rear of the FM110
can be set to enable power to
be reconnected automatically or
manually to the equipment being
controlled.
The flow sensor is made to suit
8mm bore pipe and comprises a
turbine on sapphire bearings with
a hall effect switch activated
by magnets on the turbine.
|
|
27. |
HPLC Uv detector |
Spectrophysics |
8450 |
HPLC SP 8450 UV/visible detector |
|
28. |
HPLC system complete |
Spectra physics |
7600, UV1000, sp8450, sp p2000
|
HPLC with pumping
unit, two detector units, degasser
for solvents and recorder/integrator |
|
29. |
Fieser
and fieser “reagents for
organic synthesis |
Fieser and fieser |
-- |
Multi
volume books on organic regents
for organic synthesis |
|
30. |
Food
science and technology abstracts-set |
-- |
-- |
We
have boxes of this journal from
many years |
|
31. |
Wiped film molecular still |
CVC |
Lab-3 |
Centrifugal
molecular distillation is a purification
technique which has gained wide
acceptance in the chemical, food
processing, pharmaceutical and
petroleum industries as well as
the specialty chemicals industry.
The principle behind the Myers
Vacuum Centrifugal Molecular Stills
is low pressure and extremely
short residence time. Once the
feed material has been degassed,
it flows onto the spinning heated
disc. Distillation takes place
in less than 1 second as the material
expands out exponentially on the
radius of the disc. The residue
is caught within a gutter surrounding
the rotor and then flows down
to the collecting vessel below.
The distillate condenses on the
outer shell of the still and flows
by gravity to another collecting
vessel also below the still.
The major advantages
that can be expected from the
Lab-3 Molecular Still
are:
High product
percentage yield.
Close to 1 theoretical plate.
Elimination of color bodies.
Elimination of odor fractions.
Reduction of acid values in ester
distillation.
Removal of excess reactants.
Elimination of residual metal
catalysts.
Minimized thermal hazard (a necessity
for heat sensitive compounds).
The still itself may be purchased
separately or with controls and
pumping system.
The Lab-3 has
a 3 inch diameter rotor with a
throughput capability of about
0 - 2 lbs/hour. Like the other
still models, the Lab-3, with
the pumping system will operate
around 1 micron pressure. |
|
32. |
Pope 2" Wiped-Film Molecular Still |
-- |
40468-01 |
Application
Food; Pharmaceuticals; Research
& Development; Solvent Recovery;
Polymer, Moisture Removal Type
Vacuum oil pump ; Wiped Film Evaporator
Surface (m²) 0.0325 Materials
of Construction Standard Glass
Body Power Source Electric speed
drive mechanism, self-supporting
still stand |
|